|
|
M-011 / M-011-1ML updated item number format
(±)-MDMA-D5 [(±)-3,4-Methylenedioxymethamphetamine-D5]
100 ug/mL in Methanol | Certified Reference Material
|
MDMA is an illicit drug known by a variety of street names, including "Ecstasy," "E," "X," and "XTC". An analog of the phenethylamine and amphetamine classes, MDMA is abused for its euphoric and psychedelic effects. This stable-labeled internal standard is suitable for quantitation of MDMA levels in urine, serum, or plasma by LC/MS or GC/MS for urine drug testing, clinical toxicology, forensic analysis, or isotope dilution methods.
|
|
|
|
Concentration:
|
100 ug/mL
|
Solvent:
|
Methanol
|
Unit Size:
|
1 mL/ampoule
|
CAS Number:
|
136765-43-0
|
Chemical Formula:
|
C11H10D5NO2
|
Molecular Weight:
|
198.27
|
Certificate of Analysis:
|
|
US List Price:
|
|
|
|
| A-050 / A-050-1ML |
|
Amine Mixture-6, 250 μg/mL of each component
|
|
$217.00
|
|
|
|
|
| M-010 / M-010-1ML |
|
(±)-MDA-D5 [(±)-3,4-Methylenedioxyamphetamine-D5], 100 μg/mL
|
|
$40.70
|
|
|
|
|
| M-012 / M-012-1ML |
|
(±)-MDA [(±)-3,4-Methylenedioxyamphetamine], 1.0 mg/mL
|
|
$34.80
|
|
|
|
|
| M-013 / M-013-1ML |
|
(±)-Methylenedioxymethamphetamine ((±)-MDMA), 1.0 mg/mL
|
|
$34.80
|
|
|
|
|
| M-027 / M-027-1ML |
|
(±)-MDA-D5, 1.0 mg/mL
|
|
$156.00
|
|
|
|
|
| M-029 / M-029-1ML |
|
(±)-MDMA-D5 [(±)-3,4-Methylenedioxymethamphetamine-D5], 1.0 mg/mL
|
|
$164.00
|
|
|
|
|
| M-065 / M-065-1ML |
|
(±)-MDEA [(±)-3,4-Methylenedioxyethylamphetamine], 1.0 mg/mL
|
|
$28.20
|
|
|
|
|
| M-067 / M-067-1ML |
|
(±)-MDEA-D5 [(±)-3,4-Methylenedioxyethylamphetamine-D5], 100 μg/mL
|
|
$39.10
|
|
|
|
|
| M-068 / M-068-1ML |
|
(±)-MDEA-D5 [(±)-3,4-Methylenedioxyethylamphetamine-D5], 1.0 mg/mL
|
|
$156.00
|
|
|
|
|
| M-081 / M-081-1ML |
|
(±)-MDEA-D6 [(±)-3,4-Methylenedioxyethylamphetamine-D6], 100 μg/mL
|
|
$49.90
|
|
|
|
|
| M-082 / M-082-1ML |
|
(±)-MDEA-D6 [(±)-3,4-Methylenedioxyethylamphetamine-D6], 1.0 mg/mL
|
|
$406.00
|
|
|
|
|
Regulatory Control ▶ USDEA exempt chemical preparation - no USDEA registration or paperwork required ▶ Canada Test Kit Registration # 61-1279 - no Health Canada import authorization required
read more about ordering regulated substances
UN Number, Class, PG 1230, 3, II
Safety Data Sheet
HS Code
2845.90.0100
▶ Development of a High-Throughput LC-MS/MS Assay for a Pain Management Panel from Urine | IONICS Mass Spectrometry Group inc., 2014
|
▶ Proof of Concept for Automated SPE/HPLC/MS/MS Methods to Replace Traditional Immunoassay with MS Confirmation of Driving Under the Influence Samples | Robert M. Sears, Toxicology Technical Leader , Kenneth Lewis, CEO , and Kim Gamble, President, ITSP Solutions, INC., 2014
|
▶ Rapid Screening of Amphetamine Drugs in Urine by Positive Ion Electrospray LC/MS/MS | Z. Yang and S. Sadjadi, Agilent Technologies, Inc., 2010
|
▶ Testing and Quantification of a Representative Panel of Illicit Drugs in Urine and Serum Using LC-Time-of-Flight Mass Spectrometry | Avinash Dalmia, Noelle M. Elliott, Joanne Mather, Bonnie Marmor, George Perkins;, PerkinElmer, Inc., 2014
|
|
|
|
|